b. Verify that the scsi-initiator-id for each host adapter on the second node is set to 7.
Use the show-disks command to nd the paths to the host adapters that are connected to
these enclosures. Select each host adapter's device tree node, and display the node's
properties to conrm that the scsi-initiator-id for each host adapter is set to 7.
{0} ok cd /pci@6,4000/pci@3/scsi@5
{0} ok .properties
scsi-initiator-id 00000007
...
If you did not power o Node B to install a host adapter, skip to Step 23.
If you powered o Node B to install a host adapter, perform a reconguration boot to create the
new Oracle Solaris device les and links.
Check the controller module NVSRAM le revision. If necessary, install the most recent revision.
For the NVSRAM le revision number and boot level, see the Sun StorEdge RAID Manager
Release Notes. For the procedure about how to upgrade the NVSRAM le, see the Sun StorEdge
RAID Manager User’s Guide.
Verify the controller module rmware revision. If necessary, install the most recent rmware
revision.
For the revision number and boot level of the controller module rmware, see the Sun StorEdge
RAID Manager Release Notes. For the procedure about how to upgrade the controller rmware,
see
“How to Upgrade Controller Module Firmware” on page 39.
One node at a time, boot each node into cluster mode.
# reboot
On one node, verify that the device IDs have been assigned to the LUNs for all nodes. These
nodes are attached to the storage array or storage system.
# cldevice show
(StorEdge A3500 Only) Verify that the controller module is set to active/active mode.
For more information about controller modes, see the Sun StorEdge RAID Manager Installation
and Support Guide and the Sun StorEdge RAID Manager User’s Guide.
To create a LUN from disk drives that are unassigned, see
“How to Create a LUN” on page 22.
To upgrade controller module rmware, see
“How to Upgrade Controller Module Firmware”
on page 39
.
18
19
20
21
22
23
24
See Also
Installing Storage Arrays
Chapter 1 • Installing and Maintaining a SCSI RAID Storage Device 21