Entering the Library without the Service Safety Door in Place
17-2 StorageTek SL8500 Library Guide
2.
Set the power switch to the ON position.
If the library has a 2N power configuration, switch on both PDUs.
Entering the Library without the Service Safety Door in Place
1. Follow all safety precautions (see "Safety Precautions when Entering the Library"
on page 17-2).
2. Place the library offline (see "Taking the Library Offline" on page 15-1).
3. Unlock and open the front access door. Lock the access door open and retain the
key
4. If necessary, move the robots out of your way starting with the bottom rail. Avoid
damaging the robot's mechanical or electronic components. The robot should
move freely. Do not force the robot if movement is restricted.
5. Before you exit the library, verify that there are no loose items or people in the
library.
6. Close and latch the doors.
7. Lock the doors and retain the key.
8. Bring the library online (see "Bringing the Library Online" on page 15-2).
Safety Precautions when Entering the Library
Verify the library is offline. Do not enter the library or move any of the robots if
you suspect the robots are online.
Do not attempt to override any of the electrical or mechanical safety devices in the
library.
Inform someone in the immediate area that you are going to enter the library.
Locate the mechanical door releases (yellow handles on the inside of the access
doors). If the doors close while you are inside the library, push the mechanical
release to unlock and open the door.
Always leave both the front access doors open while inside the library.
Know the physical restrictions of the library. Be careful not to bump you body or
snag clothing on the arrays (there is only 0.4 m [18 in.] of aisle clearance).
Using the Emergency Robotics Stop Switch
The emergency robotics stop (EMS) switch cuts all power to the robots.
Note: Opening an access door without the safety door in place will
stop all library operations. When the library comes back online, it will
perform a full audit. See also "Operating the Service Safety Door" on
page 17-3.
WARNING: To prevent the door from accidentally closing, lock the
access door open and retain the key.

Table of Contents

Other manuals for Oracle StorageTek SL8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle StorageTek SL8500 and is the answer not in the manual?

Oracle StorageTek SL8500 Specifications

General IconGeneral
BrandOracle
ModelStorageTek SL8500
CategoryStorage
LanguageEnglish

Related product manuals