HLI-PRC Addressing Scheme
C-8 StorageTek SL8500 Library Guide
Library 1: LSM 0 to 3
Library 2: LSM 4 to 7
Library 3: LSM 8 to 11
When adding an additional library to a complex, you should add libraries from right
to left (viewed from the CAP-side of the library). Expanding left to right re-numbers
the LSMs requiring you to reconfigure hosts.
Figure C–4 Pass-thru Port Planning Example
1.
Recommended method with the library added to the left which increases the LSM
numbering sequentially
2. Disruptive method, which requires a reconfiguration of LSM numbering.
3. New library
4. Pass-thru-port connecting existing libraries
Drive HLI-PRC Addressing
For drives, the panel value is always equal to 1, the column value is always equal to 0,
and the row value is between 0 and 15.