OPTIMOD TECHNICAL DATA
6-5
Power Supply: Current-limited 9 VDC provided for use with contact closure.
Connector: Mini DB, EMI-suppressed.
Filtering: RFI filtered.
Power
Voltage: U: 100-132 VAC; E: 200-264VAC; J: 89-120VAC, 178-240 VAC; 50VA.
Line Frequency: 50 to 60 Hz.
AC Connector: IEC, detachable 3-wire power cord supplied. AC is EMI-suppressed.
Grounding: Circuit ground is independent of chassis ground; can be isolated or connected
with a rear panel switch. There is no ground lug. However, analog power common is
available on pin 13 of the Remote Interface DB-25 connector.
Surge and Transient: According to regulatory testing requirements.
Memory Backup: All system parameters and user presets are stored in an E2PROM. No
battery is required.
Safety Standards: ETL listed to UL standards, CE marked.
Environmental
Operating Temperature Range: Model 6200 OPTIMOD-DAB, 32° to 122°F/0° to 50°C at
nominal operating voltages; Model 6200S, 32° to 113°F/0° to 45°C at nominal operating
voltages.
Humidity: 0-95% RH, non-condensing.
RFI / EMI: Tested according to Cenelec procedures.
Dimensions (W x H x D): Model 6200 OPTIMOD-DAB, 19 x 3.5 x 14.25/48.3cm x 8.8
cm x 36.2cm, two rack units high; Model 6200S, 19 x 1.75 x 13.25/48.3cm x 4.4cm x
33.7cm, one rack unit high.
Weight: 6200 OPTIMOD-DAB, 14 lbs/6.4kg; 6200S, 13 lbs/6kg.
Shipping Weight: 6200 OPTIMOD-DAB, 19 lbs/8.7kg; 6200S, 18 lbs/8.2kg.
Warranty
One Year, Parts and Labor: Subject to the limitations set forth in Orban's Standard War-
ranty Agreement.
Specifications are subject to change without notice.