2-28
INSTALLATION ORBAN Model 6200
F) Calibrate using Program — feed normal Program material to the 6200.
[Skip this step if you are using Tone to calibrate the 6200 to your standard
studio level — see step (E) above.]
Play program material from your studio, peaking at the level to which you
normally peak program material (typically 0VU if your console uses VU
meters).
a)
Verify
ST CHASSIS
is set to
no
.
Refer to step 3 on page 2-23 above.
b)
Hold down the
AI REF
soft key and use the 6200’s front panel control knob to
adjust for an average of 10dB gain reduction on the 6200’s
AGC
meter.
Also, observe the
Gate
indicator. It should go out when program is present.
If the
AGC
gain reduction meter averages less than 10dB gain reduction
(higher on the meter), or if the
Gate
indicator stays on when program mate-
rial is present, re-adjust the
AI REF
level to a lower level.
If the
AGC
gain reduction meter averages more gain reduction (lower on the
meter), re-adjust the
AI REF
level to a higher level.
This control has no effect on the AES/EBU digital input.
c)
When finished, reset ST CHASSIS to yes, if required (e.g., if that was its setting
prior to setting
AI REF level).
4. Adjust R CH BAL (Right Channel Balance).
[Skip this step if the channels are already satisfactorily balanced.]
[2dB to +2dB] on right channel only, 0.1dB steps
This is not a balance control like those found in consumer audio products.
This control changes gain of the right channel only. Use this control if the
right analog input to the 6200 is not at exactly the same level as the left in-
put. Be certain that the imbalance is not from a certain program source, but
only through distribution between the console output and 6200 input.
A)
Press
Setup
button to access Setup screen.
B) Press
I/O CALIB
soft key, then press
ANLG IN CALIB
soft key.
C) Press the
Next
button to page to the
R CH BAL
settings, then adjust the parameter,
as necessary.
5. Adjust the source of the analog output.
[Skip this step if you will not be using the 6200’s analog output.]
A) Press
Setup
button.
B) Press
I/O CALIB
soft key, then
ANLG OUT CALIB
soft key.
C) Set the
MON OUT
control to
pre limt
(pre limiter) or
post lim
(post limiter), as de-
sired.

Table of Contents