c. With the valve module connections exposed remove the servo
and hose switch interconnects from the control board and Hall
Effect switch from the base plate.
Hall Effect Switch
Hall Effect Switch - Install with the
white line up as shown
Hall Effect & Hose Switch Interconnect
Servo Interconnect
7. Valve Service – Requires Steps 2 & 6
a. Extract the valve screw and washer (#1 Phillips)