Increase Quality Through Interaction with the Field
b. First attempt to pull the fan housing assembly off the motor
shaft. If necessary use a puller to remove the fan from the motor
shaft (020510 – At this time I don’t know if they will be offered)
c. Remove and inspect the detent ring from the old motor. If free of
defect apply to the new motor, along with a felt seal and shaft
washer.
11. Fan Housing Module - Requires Steps 2, 4, 6, 9 & 10
a. To remove the scroll cover rear, extract the four screws
indicated
b. To remove the scroll cover front extract the four screws
indicated.
Detent
Felt
Seal
Washer or 2