Increase Quality Through Interaction with the Field
Electrical
1. The fuse on the logic board is for fire safety, not to protect the board.
2. If the motor current increases and the fuse doesn’t blow, then the chip will
shutdown the motor.
3. If left plugged in the unit will return to the speed in use when it was turned off. If
unplugged then the speed will rev up to full speed.
4. On the power supply board the resistor marked will blow if the board goes bad.
5. If the LEDs are On but the unit doesn’t function, turn Off, unplug, wait 30 seconds
and plug it back in. Turn it On and the unit should work.
Increase Quality Through Interaction with the Field
3
Handle Switch
On/Off High Speed Low Speed
Motor
Line
Control/Triac 110-120VAC
Line
N
eutral
Servo
Bl
ue
G
r
ou
n
d
Brown – On/Off 5vdc
Yellow – Low Speed 5vdc
Red – High Speed 5vdc
Black
Brown
Switch
White
B
Not Used
lack
Line
Red – 12 VDC
Fuse
Common - Brown
12VDC - Black
12VDC - White
White - Neutral
Hall Effect Sensor
Brown on the bottom
White in the middle
Black on top