18
02.04/WE
ORGAPACK OR-T 200
Flashing
green light
Continuous
green light
Continuous
green light
Flashing
green light
Double flashing
green light
No indicator
illuminated
4.4 BATTERY CHARGER INDICATORS
Ready for charging
Battery not inserted, mains
supply is connected.
Rapid charging
Rapid charging operates until
the battery is fully recharged.
The battery charger then
switches automatically to
trickle charging.
Trickle charging
Battery inserted, the battery
charger is delivering only a
trickle charge because the
battery is already fully
charged.
Temperature
Warning: the battery is too
hot (or too cold). Trickle
charging only.
The battery charger switches
automatically to rapid
charging when the tempera-
ture is within the permitted
range again.
Error message
Warning: battery cannot be
charged (battery or tempera-
ture sensor defective or not a
BOSCH battery).
Mains supply not connected:
electrical plug, cable or
battery charger defective.