Orion Machine Manual
Revision 3.0 Flex Stretchwrapper
15 February 2016 Troubleshooting
Page 4-5
Turntable / Tower Will Not
Rotate
No control Power / E-Stop Condi-
tion.
E-Stop button is Flashing or Green Start
button is not illuminated.
Perform E-Stop Reset (pull E-Stop button
to the out position then press the Green
Start button so that it is Illuminated. Press
Cycle reset on the Touchscreen.
Machine is in Cycle Pause.
Observe the Cycle Pause Icon on the Run
Screen. If it is illuminated, the machine is
in a Pause state.
Press Resume to resume wrapping.
VFD parameter settings are incor-
rect.
Review the parameter settings in the VFD.
Refer to the supplied VFD Manual for
procedure.
Refer to the VFD manual and the Orion
parameter settings sheet supplied with the
machine for maximum frequency settings.
Blown Fuse.
Locate Table / Tower rotation control
fuse. Remove fuse and check continuity.
Bad Fuse? Replace with correct type.
VFD Error.
Check the status of the table / tower motor
controller (VFD) for error message.
Refer to the VFD manual supplied with
the machine for error messaging solutions.
Open circuit to the motor.
Check wire continuity from VFD to
Motor.
Repair or replace open wiring.
Motor Failure.
Perform motor test per motor manufac-
turer's recommendations.
Replace Motor as needed.
Table 4-1. Troubleshooting Chart (Continued)
PROBLEM POSSIBLE CAUSE SOLUTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orion FLEX HPA and is the answer not in the manual?

Orion FLEX HPA Specifications

General IconGeneral
BrandOrion
ModelFLEX HPA
CategoryStretch Wrapping Systems
LanguageEnglish

Related product manuals