Log Event Description
System Disarmed System disarmed.
Arming Failed Arming failed.
Armed With ATS Fault The system was armed with an Alarm Transmission System (ATS) fault.
Auto Armed The system was automatically armed.
Auto Disarmed The system was automatically disarmed.
Remote Armed The system was automatically armed remotely.
Remote Disarmed The system was automatically disarmed remotely.
System Power Up The system was powered up.
AC Failed The mains AC supply has been switched off.
AC Restore The mains ac supply has been restored.
Battery Fault #X Battery fault #? (1: Presence Fail; 2: Load Test Fail).
Battery Restore Battery fault restored.
Low Battery Alarm The system standby battery voltage is low (The system is running on
battery only).
Time/Date Changed The system time and date has been changed.
Engineer on site The engineer access code has been entered.
Engineer off site The engineer has logged off.
Bell Fuse Alarm The bell fuse has gone open circuit (electronic fuse).
Bell Fuse Restore The bell fuse has restored.
Aux Fuse Alarm The auxiliary 12V fuse has gone open circuit (electronic fuse).
Aux Fuse Restore The auxiliary 12V fuse has restored.
Battery Fuse Alarm The battery fuse has gone open circuit (electronic fuse).
Battery Fuse Restore The battery fuse has restored.
Network Fuse Alarm The network fuse has gone open circuit (electronic fuse).
Network Fuse Restore The network fuse has restored.
Box Tamper Alarm The control panel box tamper has been activated.
Box Tamper Restore The control panel box tamper has restored.
Keypad X Tamper Keypad X box tamper has been activated.
Keypad X Tamp Rest Keypad X box tamper has restored.
Exp X Tamper Alarm Expander X tamper alarmed.
Exp X Tamper Restore Expander X tamper is restored.
Bell X Tamper Alarm Network Bell X tamper alarmed.
Bell X Tamper Restore Network Bell X tamper is restored.
Keypad XX Lost Keypad XX on network lost.
Keypad XX Found Keypad XX on network found.
Expander XX Lost Expander XX on network lost.