30
Log Event Description
Expander XX Found Expander XX on network found.
Bell X Lost Network Bell X on network lost.
Bell X Found Network Bell X on network found.
Walktest Started User walk test mode started.
Walktest Ended User walk test mode ended.
Bell Test Started User bell test started.
Bell Test Ended User bell test ended.
Auto Test Call An automatic test call was sent to the Alarm Receiving Centre (ARC).
Manual Test Call A manual (user) test call was sent to the Alarm Receiving Centre (ARC).
Timer X On Control Timer X is on.
Timer X Off Control Timer X is off.
Zone Test XXX Days Zone soak test has started and will run for XXX days.
Zone XX Test Fail Zone XX has failed whilst on test.
First Knock XX First activation from zone XX. The zone has the “Double Knock”
attribute.
Beam Pair 1
st
XX First activation from zone XX. The zone has the “Beam Pair” attribute.
Alarm Aborted The user has disarmed the system within the abort delay period.
Bell Tamper Alarm The bell tamper alarm has been activated.
Bell Tamper Restore The bell tamper has restored.
Bell X Fault Alarm Network Bell X fault.
Bell X Fault Restore Network Bell X restored
ATS Fault The Alarm Transmission System (ATS) has detected a fault with the
transmission path (telephone line/GSM/IP).
ATS Restored The ATS Fault has restored.
Keypad PA X A panic alarm was generated at keypad X by pressing keys 7 and 9.
Keypad Fire X A fire alarm was generated at keypad X by pressing keys 1 and 3.
Keypad Medical X A medical alarm was generated at keypad X by pressing keys 4 and 6.
Output XX Fault The control panel has detected a fault on panel output XX.
Output XX Restore The fault on panel output XX has restored.
Cleaner On-Site XX A cleaner access code has been entered.
Cleaner Off-Site XX A cleaner has logged off.
Com X Module Alarm The communication module has been disconnected/lost from com port
X
Com X Module Restore The communication module has been connected/found from com port
X
Zone XX Count Alarm Zone XX has reached the “Count Logging” threshold.