OSAKA – USER MANUAL – F 500 / F 500-RS – V.1 – Page 1
79
A.bo
(#)
Black out alarm delay
to be recorded as an
HACCP alarm
( =oF HACCP rec.
disable)
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
80
A.di
(#)
Digital input alarm AL
delay to be recorded
as an HACCP alarm
( =oF HACCP rec.
disable)
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
]Ou
o. - parameters relative to configuration of
outputs and buzzer
81
o.o1
OUT1 function:
oF= No function
ot= Temperature
control (compressor)
dF=Defrosting(1)
Fn= fan
Au= Auxiliary
At/-t= Silenceable
alarm
AL/-L= Not silenceable
Alarm
An/-n= Memorised
alarm
on = on when
instrument switch on
HE= Heating (Neutral
zone control)
2d = Defrosting 2
L1 = light with
economy mode (on
with “SP” and off with
“SPE”)
L2 = internal light (off
with door closed and
on with door opened)
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
ot
82
o.o2
OUT2 function:
see “o.o1”
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
dF
83
o.o3
OUT3 function:
see “o.o1”
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
Fn
84
o.o4
OUT4 function:
see “o.o1”
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
Au
85
o.bu
Buzzer function mode
oF = disable
1 = active alarms only
2 = key pressed only
3 = active alarms and
key pressed
oF / 1 / 2 / 3
3
86
o.Fo
Function mode
auxiliary output:
oF= No Function
1= control output “ot”
delayed
2= manual activation
by key or digital input.
oF / 1 / 2
oF
87
o.tu
Time relative to
auxiliary output
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF
]tS
t. -parameters relative to configuration of the
keyboard and serial communication
88
t.UF
Function mode Key
STAND-BY:
oF= No function
oF / 1 / 2 / 3 / 4
/ 5 / 6 / 7
oF
1= Auxiliary output
command
2= Norm. / Eco mode
Selection
3= Switch on/off
(Stand-by)
4= “Turbo” cycle
command
5 = Manual Switch
on/off (Stand-by) when
set by clock
6= HACCP Alarms
Reset
7= HACCP Alarms rec.
disable/enable
89
t.Fb
Function mode key
Down/Aux: see “t.UF”
oF / 1 / 2 / 3 / 4
/ 5 / 6 / 7
oF
90
t.Lo
Keyboard lock function
delay
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
30.0
(min.sec.x10)
oF
91
t.Ed
Set Visibility with fast
procedure by Key SET:
oF = None
1 = SP
2 = SPE
3 = SP e SPE
4 = Active SP
5 = SP and SPH
6 = SP, SPE and SPH
oF / 1 / 2 / 3 / 5
/ 6
4
92
t.PP
Access Password to
parameter functions
oF ÷ 999
oF
93
t.HA
(#)
HACCP Alarms
Parameters level
1 = protected
parameters
2 = unprotected
parameters
1 / 2
1
94
t.AS
MODBUS Station
address (for serial
communication)
0 ÷ 255
1
]cL
c. - parameters relative to clock setting
95
c.CL
(#)
Current time and
current day of the
week:
h = hour
n = min.
d = day of the week
(d.1 = Monday ... d.7 =
Sunday)
d.oF = clock disable
h. = 0 ÷ 23
n. = 0 ÷ 59
d. = oF-1 ÷ 7
96
c.dt
(#)
Current date:
y = year
M = month
d = date
y. = 10 ÷ 99
n. = 1 ÷ 12
d. = 1 ÷ 31
]cE
c. parameters relative to events occour at defined
times
97
c.01
(#)
Event 1
h = hour
n = min.
d = day of the week
(d.1 = Monday ... d.7 =
Sunday
d. 8 = every day
d. 9 = from Monday to
Friday
d.10 = from Monday to
Saturday
d.11 = Sat. and Sun.
d.oF = no day (event
disabled)
t = event type
t.1 = Switch on
t.2 = Stand-by
h. = 0 ÷ 23
n. = 0 ÷ 50
d. = oF-1 ÷ 11
t. = oF-1 ÷ 10
h.0
n.0
d.oF
t.oF