17!
Battery Replacement
When the battery level is low (one bar remains on the battery icon), an alarm will sound
repeatedly at five minute intervals. When the battery is nearly exhausted, a unique
combination of audible, LED, and LCD backlight alerts will display for approximately 10
seconds (before the unit turns off completely).
Required Items:
Phillips-head Screwdriver
Replacement Battery = SB-AA02 (Lithium ½ AA Battery, 3.6V/1.2Ah)
NOTE: Replacement of the battery in dangerous regions with potential for
explosion is strictly prohibited. Replacement of components can hinder intrinsic
safety function.
NOTE: Replacement battery kits should be purchased from the same retailer
that the device was originally purchased from.
NOTE: The device must be recalibrated following battery replacement.
NOTE: Before disassembling, power off the device according to the instructions
in this operation manual.
1
Label
2
Calibration cap
3
Front cover
4
Sensor element
5
PCB (terminal board)
6
Battery
7
Rear cover
8
Belt clip
9
Machine screw