EasyManua.ls Logo

OTT Hydrolab MS5 - User Manual

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Hydrolab DS5X, DS5, and MS5
Water Quality Multiprobes
USER MANUAL
February 2006, Edition 3
© Hach Company, 2006. All rights reserved.

Table of Contents

Questions and Answers

Summary

Section 1 Specifications

Section 2 General Information

Safety Information

Provides safety instructions and explains hazard signal words used in the manual.

Section 3 Installation

Instrument Assembly and Power Options

Details connecting the multiprobe to a display/PC and available power sources.

Section 4 Operation

Section 5 Deployment

Section 6 Maintenance

Battery Replacement

Step-by-step guides for replacing batteries in DS5, DS5X, and MS5 multiprobes.

Sensor Maintenance

Procedures for maintaining specific sensors like DO, pH, ORP, and conductivity.

Section 7 Replacement Parts and Accessories

Section 9 Repair Service

Appendix A Troubleshooting

Troubleshooting Communications

Guides on resolving communication issues with Hydras 3LT and connection problems.

Troubleshooting Sensor Issues

Lists common sensor problems and provides solutions for incorrect readings.

Appendix B External Communications

Appendix C Using HyperTerminal

Summary

Section 1 Specifications

Section 2 General Information

Safety Information

Provides safety instructions and explains hazard signal words used in the manual.

Section 3 Installation

Instrument Assembly and Power Options

Details connecting the multiprobe to a display/PC and available power sources.

Section 4 Operation

Section 5 Deployment

Section 6 Maintenance

Battery Replacement

Step-by-step guides for replacing batteries in DS5, DS5X, and MS5 multiprobes.

Sensor Maintenance

Procedures for maintaining specific sensors like DO, pH, ORP, and conductivity.

Section 7 Replacement Parts and Accessories

Section 9 Repair Service

Appendix A Troubleshooting

Troubleshooting Communications

Guides on resolving communication issues with Hydras 3LT and connection problems.

Troubleshooting Sensor Issues

Lists common sensor problems and provides solutions for incorrect readings.

Appendix B External Communications

Appendix C Using HyperTerminal

OTT Hydrolab MS5 Specifications

General IconGeneral
Operating Temperature-5 to +50 °C
Resolution Water Level0.001 m
Measurement Range Temperature-5 to +50 °C
Accuracy Temperature±0.1 °C
Resolution Temperature0.01 °C
Measurement Range Conductivity0 - 200 mS/cm
Accuracy Conductivity±1% of reading
Resolution Conductivity0.001 mS/cm
Protection ClassIP68
WeightApprox. 1.5 kg
Measurement ParametersTemperature, Conductivity
CommunicationSDI-12, RS-485, Modbus
Measurement Range Water Level0 to 10 m
MaterialPOM
Accuracy Water Level±0.05% of full scale

Related product manuals