45
GT State PWM% ChgT
255 07 50.0 005
EXIT NEXT RSTRT
Press the <NEXT> soft key to view the FORCE FLOAT, or
BULK screen.
Pressing the <FLOAT> or <BULK> soft key forces the
Charge Controller to that speci c recharging cycle and
returns to the STATUS screen. Forcing a FLOAT or BULK
recharge will end an EQ cycle. Press the <NEXT> soft key
to view the third MISCELLANEOUS screen.
• Force FLOAT =  oat cycle
• Force BULK = bulk cycle
Press the <EXIT> soft key twice to return to the MAIN
MENU.
FORCE
EXIT NEXT FLOAT BULK
PCB Target Btmp CFB
512 14.4v 255 0712
EXIT BACK
This is the assigned number representing
the temperature of the internal components
to control the cooling fan. The lower the
number, the higher the temperature. 25° C is
approximately a value of 525.
Btmp is a battery temperature sensor reference
value used to compensate the charging voltage.
This is an arbitrary number between 0 and 255
and is not the actual temperature. An ‘X’ next to
this value indicates a Global external RTS is being
used (system with a HUB and MATE).
The output value of the
internal current sensor is used
to calculate output amps,
watts, and track the Maximum
Power Point of the array.
The target voltage the
controller is trying to
reach.