1
Ins. No. S-176-9-E
Super Micro Flow Mate
FLOW MATE (OVAL M-
)
Every OVAL product is manufactured and functionally tested under stringent quality control before
shipment.
In order to maintain its design performance throughout its life, this manual offers the
operator the necessary installation, operation and maintenance information. Be well familiar with
these instructions before you place your meter in service and retain it at the eld location for ready
reference.
Super Micro 39
Fittings provided (option)
Super Micro 38
Meter Sizes 40, 4
1, and 45
MODEL LSF
□□-□
38
39
40
4
1
45

Questions and Answers

  • E
    Erika WalkerAug 9, 2025
    What to do if Oval LSF40 counts while the valve remains closed?
    • M
      Mariah MonroeAug 9, 2025
      If the Oval Accessories counter shows counts even when the valve is closed, it could be due to liquid leaks from valves or tube connections. Inspect these components for their condition. Alternatively, air might be trapped between the valve and meter, causing the rotors to rock due to pulsating pump pressure. In this case, release the trapped air and install a check valve and accumulator.
  • Y
    ysantiagoAug 16, 2025
    How to fix Oval Accessories counter that will not count?
    • G
      gilmoremichelleAug 16, 2025
      If your Oval Accessories counter isn't counting, first, progressively open the valves to ensure sufficient flow rate. Check that the pump pressure or head pressure is adequate for your tubing system. Ensure the pulse generator receives 12 to 24 VDC power. If the rotors are jammed by foreign matter, disassemble the meter body, and clean the rotors and related components. Lastly, make sure the rotors are installed correctly.
  • J
    Jacqueline ThomasAug 25, 2025
    Why is the accumulated total too high on my Oval LSF40?
    • D
      Danielle KellyAug 25, 2025
      If the accumulated total on your Oval Accessories is too high, it might be caused by a rocking motion of the rotors due to pulsating flow. To resolve this, install a check valve and accumulator. Another cause might be external magnetic fields interfering with the flow sensor. Shield the device from these fields. Also, check for entrapped air and provide an air vent to release it.
  • B
    Benjamin BishopSep 1, 2025
    How to stop liquid leaks from Oval LSF40 Accessories?
    • S
      Steve DavisSep 1, 2025
      If you notice liquid leaking from your Oval Accessories, first, tighten the tube connections or replace the gaskets to ensure a complete seal of the tubing. Also, check the front cover fitting bolts on the meter body for tightness and replace the O-ring if necessary.

Summary

2. OPERATING CONDITIONS

3. INSTALLATION

3.1 Tubing Consideration

Guidance on tubing assembly, pipe strains, and fitting installation.

4. WIRING

4.1 Field Wiring

Information on cable types and routing for field wiring.

4.2 Electrical Connections

Wiring diagrams for MR sensor and reed switch connections.

5. OPERATING INSTRUCTIONS

5.1 Operation

Step-by-step guide for the first-time operation of the meter.

5.2 Operating Precautions

5.3 Safety Precautions Before Operation Shutdown

6. DISASSEMBLY AND INSPECTION

6.1 Meter Body Disassembly and Inspection

Steps to disassemble, clean, and inspect meter body components.

6.2 Meter Body Assembly

7. TROUBLESHOOTING

8. EXPLODED VIEWS AND PARTS LISTS

9. GENERAL SPECIFICATIONS

(3) Pulse Generator

10. OUTLINE DIMENSIONS

Reed Switch Generator Provided

11. PRODUCT CODE EXPLANATION

Oval LSF40 Series Specifications

General IconGeneral
TypeSpeaker Cable
Jacket MaterialPVC
ColorBlack
Connector OptionsBare Wire, Banana Plugs, Spade Connectors
Conductor MaterialOxygen-Free Copper (OFC)
Length Options10ft, 25ft, 50ft, 100ft
SeriesLSF40

Related product manuals