EasyManua.ls Logo

Owon HDS242 - Arbitrary Waveform Generator Specifications; Waveform Generator Performance Specs

Owon HDS242
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Basic
function
Range
Minimum
resolution
Accuracy
AC current
[1]
200.00mA
0.01mA
±( 1%+10dig)
10.000A
1mA
±( 2.8%+10dig)
frequency range40Hz-1000Hz
Overload protection:
mA function: self-healing fuse 400 mA/250 V; Ampere functio
n: 10A/600 V, D5.2*20, fast-acting fuse
Resistance
200.0
0.01Ω
±(0.8%+10dig)
2.0000kΩ
0.1Ω
±(0.8%+5dig)
20.000
±(0.8%+3dig)
200.00kΩ
10Ω
2.0000MΩ
0.1kΩ
20.000MΩ
1kΩ
±( 1%+3dig)
100.00MΩ
0.01MΩ
±( 5%+10dig)
Capacitance
[1]
20.000nF
1pF
±(3.0%+10dig)
200.00nF
10pF
2.0000μF
0.1nF
20.000μF
1nF
200.00μF
10nF
2.0000mF
0.1uF
Others
On/Off test
(<50Ω)
Diode test
(<0-2V)
Auto range
TRMS
[1] When measuring AC voltage/current or capacitance, accuracy guarantee range is 5% to
100% of the range.
Arbitrary Waveform Generator (Optional)
Characteristics
Description
Waveform Frequency
Sine
0.1Hz~25MHz
Square
0.1Hz~5MHz
Ramp
0.1Hz~1MHz
Pulse
0.1Hz~5MHz
EXP
0.1Hz~5MHz
Sampling
125MSa/s
Amplitude(50Ω)
0.01Vpp ~ 2.5Vpp

Other manuals for Owon HDS242

Related product manuals