EasyManua.ls Logo

Pacojet 4 - Error Messages

Pacojet 4
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
© Pacojet International AG 2022
ERROR MESSAGES
Code Description Behavior Text
001
Motor controller unavailable Log entry, notice:
Device error – please restart
Could not communicate
with motor controller
002
Tool detection unresponsive Log entry Tool sensor unresponsive
006
Overpressure sensor
unresponsive
Log entry Tool sensor unresponsive
007
Beaker detection failure Log entry, notice:
Device error – please restart.
Machine locked.
Improper condition of the
beaker sensors
008
Touch controller
unresponsive
Log entry Could not communicate
with touch sensor
009
Display unresponsive Log entry Could not communicate
with display
010
Valve control unresponsive Log entry, notice:
Device error
Improper condition of the
pressure valve
011
Motor fault
Torque motor overcurrent
Log entry, notice:
Mass too hard
Processing mass is too hard
012
Motor fault
Feed motor overcurrent
Log entry, notice:
Mass too hard
Processing mass is too hard
013
Overload Log entry, notice:
Mass too hard
Processing mass is too hard
014
Undervoltage Log entry, notice:
Mass too hard
Processing mass is too hard
015
Motor speed feedback false Log entry, notice:
Mass too hard
Processing mass is too hard
016
Pump fault (improper
current consumption)
Log entry A pump error has occurred
019
Incompatible motor
controller firmware
Log entry, notice:
Device error – please restart.
Machine locked.
The firmware of the motor
controller does not match
specification
021
EEPROM unavailable Log entry EEPROM unavailable
022
MPC not calibrated Log entry, notice:
Device error – please restart.
Machine locked.
Could not calibrate motor
controller
023
HMI system error – restarted Log entry, notice: Restarted
due to unrecognized error
System had to restart
due to locking up
024
MPC update unsuccessful Log entry Could not update motor
controller
025
Hall sensors plausibility
check failed
Log entry, notice:
Device error – please restart.
Machine locked.
Improper condition of the
hall sensors
Note: The error messages list was last updated 08/23 before printing. Please visit www.pacojet.com/
customer service for the latest update.