EasyManua.ls Logo

Palfinger PTV 35 - 9 Troubleshooting; Basic Function Check; Liftgate Is Competely Dead (no Clicking or Movement at All)

Palfinger PTV 35
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PTV 33/44/55/66 Owner’s Manual
Rev. 1.0 34
9 Troubleshooting
Dangerous injuries are possible from objects such as tools short circuiting main battery connections.
Be sure that you are working in a safe environment.
Change oil after working on hydraulic unit (removal of valves, opening of cylinder etc.).
There is a possibility of injury if somebody other than an authorized technician works on the electrical
system!
9.1 Basic Function Check
9.1.1 Liftgate is competely Dead (No Clicking or Movement at all)
1. Check the cab shut off switch:
Turn on cab switch, located in the cab next to the steering wheel. Location may vary by model and year of
truck. On trailer units, you will find a toggle switch near rear curb side corner post to activate the gate.
Cab
Shutoff
Switch
OFF
ON
Switch arrow
point to OFF
ON/OFF
Switch on
Outside of
Enclosure
2. Check the circuit breaker at the main batteries:
Every truck has a circuit breaker on top of the main battery. Trailers and some trucks are equipped with an
auxiliary battery kit as shown in the pictures below (“Truck Battery” and “Auxiliary Battery”).
If circuit breaker reset arm is popped out, push it back in as shown on the decal ATG-BKR next to your
breaker or on battery box lid.
Resettable
Circuit
Breaker
Dual Pump & Motor Circuit Breaker Configuration
Single Pump & Motor Circuit Breaker Configuration
Resettable
Circuit
Breakers
ON/OFF
Switch
ON/OFF
Switch
Circuit
Breaker
at Vehicle
Batteries
Reset Required.
Push tab inside.
Reset tab is
not exposed
RESET
RESET