165
Menu : Menu Description Tables
Menu
z When the digital battery is attached in the unit, the
remaining capacity of the battery is displayed in percent.
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Data Saved
Adjustable
Range
Remarks
PAG L 95
¢
•
Enable selection under BATTERY
SELECT.
¢:Enable selection.
•: Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL
:Set voltage manually.
11.0
:
13.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.
–CUF–
BP-GL60/90
¢
•
Enable selection under BATTERY
SELECT.
¢:Enable selection.
•: Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL
:Set voltage manually.
11.0
:
13.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.
–CUF–
BATTERY SETTING2
Items/
Data Saved
Adjustable
Range
Remarks
NiCd14
¢
•
Enable selection under BATTERY
SELECT.
¢:Enable selection.
•: Disable selection.
NEAR END 11.0
:
13.8
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
13.4
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
TYPE A
¢
•
Enable selection under BATTERY
SELECT.
¢:Enable selection.
•: Disable selection.
FULL 12.0
:
15.1
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
13.6
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
12.9
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
TYPE B
¢
•
Enable selection under BATTERY
SELECT.
¢:Enable selection.
•: Disable selection.
FULL 12.0
:
15.2
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
13.0
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
12.4
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
AJ-HPX2100E(English).book 165 ページ 2006年11月27日 月曜日 午後4時34分