– 88 –
Chapter 4 Operation — Menu setting contents
[PRE REC]
Sets whether to perform pre-recording.
The pre-recording time differs depending on the setting of the [SYSTEM SETTINGS] menu → [SYSTEM MODE] → [MAIN PIXEL]/[MAIN CODEC].
[ON] Performs the pre-recording.
The pre-recording time is as follows.
f When [MAIN PIXEL] is [1280x720], [1920x1080], or [2048x1080]: Approximately 10 seconds
f When [MAIN CODEC] is [422ALL-I 400M]: Approximately 3 seconds
f Other than above: Approximately 5 seconds
[OFF] Does not perform the pre-recording.
(Factory setting: [OFF])
@@
NOTE
t For the combination that can be set and restriction, refer to “Recording function that cannot be used simultaneously”.
[REC FUNCTION]
[REC MODE]
Selects the recording mode.
[NORMAL] Performs the standard recording.
[INTERVAL] Performs the interval recording. (A function to repeatedly perform the operation of one frame recording in set time interval.)
(Factory setting: [NORMAL])
@@
NOTE
t For the combination that can be set and restriction, refer to “Recording function that cannot be used simultaneously”.
[INTERVAL TIME]
Sets the interval duration for interval recording.
The items that can be set are as follows.
f [1s], [2s], [5s], [10s], [30s], [1min], [5min], [10min]
(Factory setting: [5min])
[TC]
[SET TC]
Sets the default value of the time code to record.
Hour [00]…[23]
Minute [00]…[59]
Second [00]…[59]
Frame [00] … [23] (when [24.00p] or [23.98p] is set)
[00] … [24] (when [50.00i], [50.00p], or [25.00p] is set)
[00] … [29] (when [59.94i], [59.94p], or [29.97p] is set)
(Factory setting: [00]) (each item)
[SET UB]
Sets user bits.
Enabled only when [USER] is selected in [UB MODE] of [TC].
Each digit can be set in following range.
f [00]…[FF]
(Factory setting: [00])
[TC/UB/Dur.]
Switches the time code display to the user bits or duration counter display.
The items that can be set are as follows.
[TC] Time code display
[UB] User bits display
[Dur.] Duration counter display
(Factory setting: [TC])
[FREE/REC RUN]
Sets the operation mode to advance the time code generator.
[FREE RUN] Advances regardless of the operation mode.
[REC RUN] Advances only while recording.
(Factory setting: [FREE RUN])