EasyManua.ls Logo

Panasonic CS-BE35TKE-1 - Outdoor Unit Wiring Diagram

Panasonic CS-BE35TKE-1
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
8.2 Outdoor Unit
Resistance of Compressor Windings
MODEL BE/DE25TKE-1 BE/DE35TKE-1
CONNECTION ASK75D43UEE ASK75D43UEE
U-V 2.18 2.18
U-W 2.18 2.18
V-W 2.18 2.18
Note: Resistance at 20°C of ambient temperature.
TERMINAL
BOARD
TO INDOOR UNIT
COMPRESSOR
OUTDOOR AIR TEMP.
SENSOR
(THERMISTOR)
PIPING TEMP. SENSOR
(THERMISTOR)
1
4
AC-WHT
(WHT)
CN-MTR1
(RED)
CN-MTR2
(WHT)
IC19
Q1
FG1
(GRN)
FG2
(GRN)
GRN
BLK
WHT
GRN
AC-BLK
(BLK)
DATA
(RED)
RED
GRY
RAT2
(GRY)
GRY
YLW
YLW
RAT1
(GRY)
REACTOR
RED
BLU
YLW
U (RED)
FUSE103
T3.15A L250V
V (BLU)
W (YLW)
U
V
W
3
5
3
1
10
14
16
1
COMP. TEMPERATURE
SENSOR (THERMISTOR)
1
3
CN-TANK
(WHT)
ELECTRO-MAGNETIC
COIL (4-WAYS VALVE)
ELECTRO-MAGNETIC
COIL (EXPANSION VALVE
)
1
3
CN-HOT
(WHT)
CN-TH
(WHT)
1
6
CN-STM
(WHT)
P
N
SWITCHING
POWER
SUPPLY CIRCUIT
FUSE102
T3.15A L250V
FUSE101
(20A 250V)
321
COMMUNICATION
CIRCUIT
PFC
CIRCUIT
W
U
V
FAN MOTOR
ELECTRONIC CONTROLLER
MS
3 ~
FUSE104
(15A 250V)
NOISE
FILTER
CIRCUIT
RECTIFICATION
CIRCUIT
RECTIFICATION
CIRCUIT
RED (RED)
(TRADEMARK)
BLUE (BLU)
THE PARENTHESIZED LETTERS IS
INDICATED ON TERMINAL COVER.
YELLOW (YLW)
COMPRESSOR TERMINAL
REMARKS
BLACK: (BLK) RED: (RED)
WHITE: (WHT) BROWN: (BRW)
YELLOW: (YLW) GREEN: (GRN)
ORANGE: (ORG) GRAY: (GRY)
BLUE: (BLU) YELLOW/GREEN: (YLW/GRN)
MS
3 ~
M

Table of Contents

Related product manuals