18.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 220-230V (CS/CU-BE35TKE-1), 230V (CS/CU-DE35TKE-1)
18.2.1 CS-BE25TKE-1 CU-BE25TKE-1
Indoor Discharge
Air Temperature (°C)
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
-20 -15 -10 -5 0 5 10 15
-20 -15 -10 -5 0 5 10 15
Outdoor Air Temperature (°C)
-20 -15 -10 -5 0 5 10 15
High Pressure (MPa) Current (A)
220V 230V
1.50
2.00
2.50
3.00
3.50
4.00
4.50
1.00
1.50
2.00
2.50
3.00
3.50
15
20
25
30
35
40
45
50

Table of Contents