4  To enter zone 2 area: (Press   continuously for T ≥ 5 secs) 
 
 
 
5  Function & Options list: 
Note: The functions described in the table may not be applicable to the model and may subject to change 
without further notice. 
 
  Function  Options Remark 
 No  Name     
Zone 1 
1  Remote control number selection  A, B, C, D   
2  Solar radiation sensitivity level adjustment  1, 2, 3, 4, 5   
3 
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [Low2] 
selection 
16°C ~ [High2]   
4 
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [High2] 
selection 
[Low2] ~ 30°C   
5  Heat mode set temperature Low1 selection  16°C ~ [High1]   
6  Heat mode set temperature High1 selection  [Low1] ~ 30°C   
7  Filter cleaning disable/enable selection  00 / 01   
8  nanoe-G default ON disable/enable selection  00 / 01   
9  Dust sensor monitoring & LED disable/enable selection  00 / 01   
10  Auto restart disable/enable selection  00 / 01   
11  Dust sensor sensitivity level adjustment  1, 2, 3   
12 ~ 49  Reserve     
Zone 2 
50  ECO demo ON  None (No display)   
51  Light sensor check  None (No display)   
52  nanoe-G / ECO sensor check  None (No display)   
53  DOA check  None (No display)   
54  Odor cut control selection [Enable (01) / Disable (00)]  00 / 01   
55  Frequency tolerance selection [±3Hz (03) / ±7Hz (07)]  03 / 07   
56 
Fixed fan speed selection during heat mode compressor OFF 
[Enable (01) / Disable (00)] 
00/01  
57  nanoe check  None (No display)   
58  Heat mode thermo shift adjustment  -3°C ~ 3°C   
59  Others (Cool & Dry) mode thermo shift adjustment  -3°C ~ 3°C   
60 
Deice start determination judgment temperature switching [Yes (01) / 
No (00)] 
00/01  
61  Cool mode disable selection [Yes (01) / No (00)]  00/01   
62  Heat mode disable selection [Yes (01) / No (00)]  00/01   
63  Base pan heater selection [Base pan A (A) / Base pan B (b)]  A / b   
64 
Disable fan speed reduction during cool mode thermo-Off [Yes (01) / 
No (00)] 
00/01  
65  LED smart OFF selection 
00 – Disable /  
01 – Enable 
 
66  nanoe-g ON/OFF duration selection 
01 – Pattern 1 /  
02 – Pattern 2 /  
03 – Pattern 3 /  
04 – Pattern 4 
 
67  Operation OFF deice function selection 
00 – Disable /  
01 – Enable 
 
68  Compressor frequency change speed selection 
01 – Pattern 1 /  
02 – Pattern 2 /  
03 – Pattern 3 
 
69 ~ 99  Reserve     
Once T ≥ 5secs
Enter Zone2
[range (50~99)]
Enter Zone1Normal display
mode