15.5.19 F11 (4-way valve Abnormality)
Malfunction Decision Conditions
When indoor heat exchanger is cold during heating (except deice) or when indoor heat exchanger is hot during
cooling and compressor operating, the 4-way valve is detected as malfunction.
Malfunction Caused
Indoor heat exchanger (pipe) thermistor
4-way valve malfunction
Troubleshooting
* Check gas side pipe – for hot gas flow in cooling mode
YES
YES
YES
NO
NO, it happen in cooling/dry as well
NO
Outdoor PCB fault
Replace
Outdoor PCB
No
Good
Reconnect CN-HOT
(4-way valve connector)
No
Good
Attach and screw the V-coil
to solenoid valve
No
continuity
(open)
Remove CN-HOT.
Measure continuity
of the coil
V-coil fault
Replace
V-coil only
Reverse solenoid valve faulty
Replace the 4-way valve
Outdoor PCB fault
Replace Outdoor PCB
No supply
OK
OK
OK
When abnormality starts again
Check the indoor pipe temperature
thermistor:
Plug out connector (CN-TH) from the
indoor unit PCB
Measure the resistance of the indoor
heat exchanger temperature thermistor
The 4-way valve may have been damaged
or wrongly connected between discharge
and suction tube
Check connecting tubes to 4-way valve
Is the measured resistance of the indoor
pipe temperature thermistor matches the
value specified in its characteristic chart?
Problem occurs in heating mode only?
Defect in indoor pipe temperature
thermistor
Replace the indoor pipe temperature
thermistor
Is 4-way solenoid valve being energised?
4-way valve not working
(not energize)
Check CN-HOT
connection
(4-way valve connector)
Check V-coil attach to
solenoid valve
Check valve v-coil
continuity
Measure voltage
supplied to CH-HOT at
the start of heating
For safety reason and to prevent component
breakdown, always switch off the power before
remove and connect the component.
OK (Depending on 4-way valve model)
YELLOW
2
1
COIL COMPLETE
CN-HOT
(WHT)
YELLOW
4 WAYS VALVE
CN-HOT
(VH9-2)
4 WAYS
VALVE
321