8 
Model 
Indoor CS-DE25TKE-1  CS-DE35TKE-1 
Outdoor CU-DE25TKE-1  CU-DE35TKE-1 
Performance Test Condition  EUROVENT  EUROVENT 
Power Supply 
Phase, Hz  Single, 50  Single, 50 
V 230  230 
 Min. Mid. Max. Min. Mid. Max. 
Cooling 
Capacity 
kW  0.85 2.50 3.00 0.85 3.40 3.90 
BTU/h 2900 8530 10200 2900 11600 13300 
kcal/h  730 2150 2580 730 2920 3350 
Running Current  A  – 3.15 –  – 5.00 – 
Input Power  W  250 710 930 255 1.11k 1.32k 
Annual Consumption kWh  – 355 –  – 555 – 
EER 
W/W  3.40 3.52 3.23 3.33 3.06 2.95 
BTU/hW  11.60 12.01 10.97 11.37 10.45 10.08 
kcal/hW  2.92 3.03 2.77 2.86 2.63 2.54 
ErP 
Pdesign kW  2.5  3.4 
SEER (W/W)  5.8  5.6 
Annual 
Consumption 
kWh 151  213 
Class   A+  A+ 
Power Factor  %  – 98 –  – 97 – 
Indoor Noise 
dB-A (H/L/Q-Lo)  37 / 26 / 20  38 / 30 / 20 
Power Level dB  53 / 42 / 36  54 / 46 / 36 
Outdoor Noise 
dB-A (H/L/Q-Lo)  48 / - / -  48 / - / - 
Power Level dB  64 / - / -  64 / - / - 
Heating 
Capacity 
kW  0.80 3.15 3.60 0.80 3.84 4.40 
BTU/h 2730 10700 12300 2730 13100 15000 
kcal/h  690 2710 3100 690 3300 3780 
Running Current  A  – 3.45 –  – 4.55 – 
Input Power  W  195  780 1.04k 195 1.04k 1.28k 
COP 
W/W  4.10 4.04 3.46 4.10 3.69 3.44 
BTU/hW  14.00 13.72 11.83 14.00 12.60 11.72 
kcal/hW  3.54 3.47 2.98 3.54 3.17 2.95 
ErP 
Pdesign kW  1.9  2.4 
Tbivalent °C  -10  -10 
SCOP (W/W)  4.0  4.0 
Annual 
Consumption 
kWh 665  840 
Class   A+  A+ 
Power Factor  %  – 98 –  – 99 – 
Indoor Noise 
dB-A (H/L/Q-Lo)  37 / 27 / 24  38 / 33 / 25 
Power Level dB  53 / 43 / 40  54 / 49 / 41 
Outdoor Noise 
dB-A (H/L/Q-Lo)  49 / - / -  50 / - / - 
Power Level dB  64 / - / -  65 / - / - 
Low Temp. : Capacity (kW) / I.Power (W) / COP  2.61 / 920 / 2.84  3.19 / 1.13k / 2.82 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP  2.14 / 860 / 2.49  2.60 / 1.05k / 2.48 
Max Current (A) / Max Input Power (W)  5.3 / 1.08k  7.0 / 1.47k 
Starting Current (A)  3.45  5.00