8.8. Random Auto Restart Control
•
If there is a power failure, operation will be automatically restarted after 3 to 5 1/2 minutes when the power is resumed.
It will start with previous operation mode and airflow direction.
•
Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
•
Auto Restart Control is not available when Timer or Sleep Mode is set.
•
This control can be omitted by open the circuit of JX1. (Refer Circuit Diagram)
8.9. Indoor Fan Speed Control
•
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
•
Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Random Fan Speed
23