6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type Backward Fan Propeller Fan
Material ABS + GF 10% PP
Motor Type DC Brushless Motor (8-pole) Transistor (8-pole)
Output Power W 40 40
Fan Speed
QLo (Cool/Heat) rpm 350 / 410 —
Lo (Cool/Heat) rpm 400 / 440 —
Me (Cool/Heat) rpm 480 / 510 —
Hi (Cool/Heat) rpm 560 / 580 750 / 720
SHi (Cool/Heat) rpm 600 / 630 —
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 × 10 × 18 2 × 24 × 17
Size (W x H x L) mm
1330 × 210 × 25.4 18.2 × 504 × 713
1270
Item Unit
Power Source (Phase, Voltage, Cycle)
øSingle
V 230 - 240
Hz 50
Input Power W
Cooling; 620 (145 ~ 870)
Heating; 820 (125 ~ 1.45k)
Starting Current A 3.8
Running Current A
Cooling; 2.9 - 2.8
Heating; 3.8 - 3.7
Maximum Current A 6.7
Power Factor %
Cooling; 93 - 92
Heating; 94 - 92
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
—
Length m
—
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT