6
1. Cooling capacities are based on indoor temperature of 27qC Dry Bulb (80.6qF Dry Bulb), 19.0qC Wet Bulb (66.2qF Wet Bulb)
and outdoor air temperature of 35qC Dry Bulb (95qF Dry Bulb), 24qC Wet Bulb (75.2qF Wet Bulb)
2. Heating capacities are based on indoor temperature of 20qC Dry Bulb (68qF Dry Bulb) and outdoor air temperature of 7qC Dry
Bulb (44.6qF Dry Bulb), 6qC Wet Bulb (42.8qF Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type Cross-Flow Fan Propeller Fan
Material ASHT-18 PP
Motor Type Transistor (8-pole) Transistor (8-pole)
Input Power W 68 62.1
Output Power W 30 40
Fan Speed
Q-Lo (Cool/Heat) rpm 1080 / 1170 —
Lo (Cool/Heat) rpm 1160 / 1240 —
Me (Cool/Heat) rpm 1295 / 1410 —
Hi (Cool/Heat) rpm 1430 / 1580 660 / 640
SHi (Cool/Heat) rpm 1570 / 1660 —
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 19 2 x 34 x 16
Size (W x H x L) mm 810 x 315 x 25.4
36.4 x 714 x 803
831
Air Filter
Material Polypropelene —
Type One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
øSingle
V 230
Hz 50
Input Power W
Cooling; 1.65k (215 ~ 2.05k)
Heating; 1.79k (245 ~ 2.65k)
Starting Current A 8.1
Running Current A
Cooling; 7.5
Heating; 8.1
Maximum Current A 11.9
Power Factor %
Cooling; 96
Heating; 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core —
Length m —
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT