7
2.2. Outdoor Unit: CU-3E18EBE
Outdoor unit Indoor unit combination Operation
mode
Capacity (kW) Power Input (kW) Current (A)
Operation Class (kW) Rating mini - max Rating mini - max
CU-3E18EBE One-room
Operation
2.2 Cooling 2.20 1.8 - 2.9 0.50 0.34 - 0.81 2.5
Heating 3.20 1.2 - 4.1 0.74 0.30 - 1.23 3.7
2.8 Cooling 2.80 1.8 - 2.9 0.70 0.34 - 0.81 3.3
Heating 4.00 1.2 - 4.3 1.05 0.30 - 1.23 5.0
3.2 Cooling 3.20 1.8 - 3.8 0.80 0.34 - 1.36 3.7
Heating 4.50 1.2 - 5.8 1.23 0.30 - 2.10 5.8
4.0 Cooling 4.00 1.8 - 4.3 1.24 0.34 - 1.99 5.6
Heating 5.60 1.2 - 6.8 1.72 0.30 - 2.93 7.7
5.0 Cooling 5.00 1.9 - 5.7 1.55 0.34 - 2.13 6.8
Heating 6.80 1.2 - 6.9 2.10 0.30 - 2.52 9.2
Two-room
Operation
2.2 + 2.2 Cooling 4.40 1.9 - 6.2 1.11 0.35 - 2.10 4.9
Heating 5.80 1.4 - 7.0 1.45 0.31 - 2.55 6.4
2.2 + 2.8 Cooling 5.00 1.9 - 6.2 1.41 0.35 - 2.10 6.2
Heating 6.40 1.4 - 7.0 1.72 0.31 - 2.55 7.6
2.2 + 3.2 Cooling 5.20 1.9 - 6.3 1.49 0.35 - 2.11 6.6
Heating 6.80 1.4 - 7.3 1.84 0.31 - 2.52 8.2
2.2 + 4.0 Cooling 5.20 1.9 - 6.4 1.45 0.35 - 2.11 6.4
Heating 6.80 1.4 - 7.3 1.80 0.31 - 2.51 7.9
2.2 + 5.0 Cooling 5.20 1.9 - 6.8 1.29 0.36 - 2.15 5.7
Heating 6.80 1.4 - 8.0 1.52 0.31 - 2.20 6.7
2.8 + 2.8 Cooling 5.20 1.9 - 6.2 1.54 0.35 - 2.10 6.8
Heating 6.80 1.4 - 7.0 1.93 0.31 - 2.55 8.5
2.8 + 3.2 Cooling 5.20 1.9 - 6.3 1.48 0.35 - 2.11 6.5
Heating 6.80 1.4 - 7.3 1.84 0.31 - 2.52 8.1
2.8 + 4.0 Cooling 5.20 1.9 - 6.4 1.44 0.35 - 2.11 6.4
Heating 6.80 1.4 - 7.3 1.80 0.31 - 2.51 8.0
2.8 + 5.0 Cooling 5.20 1.9 - 6.8 1.29 0.36 - 2.15 5.7
Heating 6.80 1.4 - 8.0 1.52 0.31 - 2.20 6.7
3.2 + 3.2 Cooling 5.20 1.9 - 6.4 1.45 0.35 - 2.12 6.4
Heating 6.80 1.4 - 7.5 1.75 0.31 - 2.49 7.7
3.2 + 4.0 Cooling 5.20 1.9 - 6.5 1.41 0.35 - 2.12 6.3
Heating 6.80 1.4 - 7.5 1.75 0.31 - 2.47 7.8
3.2 + 5.0 Cooling 5.20 1.9 - 6.9 1.25 0.35 - 2.15 5.5
Heating 6.80 1.4 - 8.0 1.50 0.31 - 2.18 6.6
4.0 + 4.0 Cooling 5.20 1.9 - 6.5 1.41 0.36 - 2.12 6.2
Heating 6.80 1.4 - 7.6 1.71 0.31 - 2.47 7.5
4.0 + 5.0 Cooling 5.20 1.9 - 6.9 1.25 0.35 - 2.16 5.5
Heating 6.80 1.4 - 8.0 1.50 0.31 - 2.17 6.6
Three-room
Operation
2.2 + 2.2 +
2.2
Cooling 5.20 1.9 - 7.2 1.24 0.36 - 2.17 5.4
Heating 6.78 1.5 - 8.1 1.53 0.32 - 2.12 6.7
2.2 + 2.2 +
2.8
Cooling 5.20 1.9 - 7.2 1.24 0.36 - 2.17 5.4
Heating 6.80 1.5 - 8.1 1.53 0.32 - 2.12 6.7
2.2 + 2.2 +
3.2
Cooling 5.20 1.9 - 7.2 1.23 0.36 - 2.18 5.4
Heating 6.80 1.4 - 8.3 1.49 0.32 - 2.11 6.5
2.2 + 2.2 +
4.0
Cooling 5.20 1.8 - 7.2 1.23 0.36 - 2.18 5.4
Heating 6.80 1.6 - 8.3 1.46 0.32 - 2.11 6.4
2.2 + 2.8 +
2.8
Cooling 5.20 1.9 - 7.2 1.24 0.36 - 2.17 5.4
Heating 6.80 1.5 - 8.1 1.53 0.32 - 2.12 6.7
2.2 + 2.8 +
3.2
Cooling 5.20 1.9 - 7.2 1.23 0.36 - 2.18 5.4
Heating 6.80 1.4 - 8.3 1.49 0.32 - 2.11 6.5
2.2 + 2.8 +
4.0
Cooling 5.20 1.8 - 7.3 1.22 0.36 - 2.18 5.4
Heating 6.80 1.6 - 8.3 1.42 0.32 - 2.11 6.5
2.2 + 3.2 +
3.2
Cooling 5.20 1.8 - 7.3 1.22 0.36 - 2.18 5.4
Heating 6.80 1.6 - 8.3 1.43 0.32 - 2.10 6.3
2.8 + 2.8 +
2.8
Cooling 5.19 1.9 - 7.2 1.24 0.36 - 2.17 5.4
Heating 6.80 1.5 - 8.1 1.53 0.32 - 2.12 6.7