12
Indoor CS-E18PKEW, CS-XE18PKEW CS-E21PKEW, CS-XE21PKEW
Model
Outdoor CU-E18PKE CU-E21PKE
Performance Test Condition EUROVENT EUROVENT
Phase, Hz Single, 50 Single, 50
Power Supply
V 230 230
Min. Mid. Max. Min. Mid. Max.
kW 0.98 5.00 6.00 0.98 6.30 7.10
BTU/h 3340 17100 20500 3340 21500 24200
Capacity
Kcal/h 840 4300 5160 840 5420 6110
Running Current A – 6.4 – – 9.7 –
Input Power W 280 1.44k 1.99k 280 2.18k 2.50k
Annual Consumption kWh 720 – 1090 –
W/W 3.50 3.47 2.96 3.50 2.89 2.84
BTU/hW 11.93 11.88 10.10 11.93 9.86 9.68
EER
Kcal/hW 3.00 2.99 2.54 3.00 2.49 2.44
Pdesign kW 5.0 6.3
SEER (W/W) 6.9 6.5
Annual
Consumption
kWh 254 339
ErP
Class A++ A++
Power Factor % – 98 – – 98 –
dB-A 44 / 37 / 34 45 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB 60 / – 61 / –
dB-A 47 / – 48 / –
Cooling
Outdoor Noise (H / L)
Power Level dB 61 / – 62 / –
kW 0.98 5.80 8.00 0.98 7.20 8.50
BTU/h 3340 19800 27300 3340 24600 29000
Capacity
Kcal/h 840 4990 6880 840 6190 7310
Running Current A – 6.8 – – 9.4 –
Input Power W 340 1.52k 2.57k 340 2.09k 2.73k
W/W 2.88 3.82 3.11 2.88 3.44 3.11
BTU/hW 9.82 13.03 10.62 9.82 11.77 10.62
COP
Kcal/hW 2.47 3.28 2.68 2.47 2.96 2.68
Pdesign kW 4.4 4.6
Tbivalent °C -10 -10
SCOP (W/W) 4.2 4.0
Annual
Consumption
kWh 1467 1610
ErP
Class A+ A+
Power Factor % – 97 – – 97 –
dB-A 44 / 37 / 34 45 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB 60 / – 61 / –
dB-A 47 / – 49 / –
Heating
Outdoor Noise (H / L)
Power Level dB 61 / – 63 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 5.80 / 2.27k / 2.56 6.16 / 2.42k / 2.55
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 4.98 / 2.39k / 2.08 5.24 / 2.52k / 2.08
Max Current (A) / Max Input Power (W) 11.3 / 2.57k 11.9 / 2.73k
Starting Current (A) 6.8 9.7