8
Indoor CS-E7PKEW, CS-XE7PKEW CS-E9PKEW, CS-XE9PKEW
Model
Outdoor CU-E7PKE CU-E9PKE
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) 3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft) 15.0 (49.2) 15.0 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2)
Piping
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Inner Diameter mm 16.7 16.7
Drain Hose
Length mm 650 650
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row × Stage × FPI 2 × 17 × 17 2 × 17 × 17
Indoor Heat
Exchanger
Size (W × H × L) mm 636.5 × 357 × 25.4 636.5 × 357 × 25.4
Fin Material Aluminium Aluminium
Fin Type Corrugated Fin Corrugated Fin
Row × Stage × FPI 1 × 20 × 19 2 × 24 × 17
Outdoor
Heat
Exchanger
Size (W × H × L) mm 22 × 508 × 708.4 36.4 × 504 × 713:684
Material Polypropelene Polypropelene
Air Filter
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A Nil Nil
Thermostat Electronic Contol Electronic Contol
Protection Device Electronic Contol Electronic Contol
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Maximum °C 32 23 32 23
Cooling
Minimum °C 16 11 16 11
Maximum °C 30 – 30 –
Indoor
Operation
Range
Heating
Minimum °C 16 – 16 –
Maximum °C 43 26 43 26
Cooling
Minimum °C -10 – -10 –
Maximum °C 24 18 24 18
Outdoor
Operation
Range
Heating
Minimum °C -15 -16 -15 -16
1. Cooling capacities are based on indoor temperature of 27°C Dry Bu b (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bu b) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bu b), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Standby power consumption 0.7w (when switched OFF by remote control, except under self protection control).
6. Specifications are subjected to change without prior notice for further improvement.