12.14.1.7 Setting Position Judgment
According to installation position when there is only one activity area detected, the horizontal airflow direction
louver position is fixed according to chart below:
Horizontal airflow direction louver position
Target area
Left installation Center installation Right installation
A 3 2 2
B 1 1 1
C 5 5 4
Louver position refer to horizontal airflow direction control.
When 2 activity areas have been detected, according to Human Activity Level, the timing of horizontal airflow
direction louver steps at the targeted activity areas is judged.
Operation Mode Activity level difference Louver stop time
Higher Activity level 60 seconds
1 level
Lower Activity level 30 seconds
Higher Activity level 60 seconds
Cooling
2 levels
Lower Activity level 8 seconds
When 3 activity areas have been detected, according to Human Activity Level the timing of horizontal airflow
louver steps at the targeted activity areas is judged.
Operation Mode Activity level Louver stop time
Hi 45 seconds
Me 30 seconds
Cooling
Lo 20 seconds
When 3 activity areas have same activity level, the horizontal airflow direction louver will swing left and right.
12.14.1.8 Setting Temperature and Fan Speed Shift
Cooling Dual Sensor
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.