16
Model
Indoor CS-MTZ16TKE
Outdoor CU-3RE18SBE
Dimension
Height (I/D) mm (inch) 290 (11-7/16)
Width (I/D) mm (inch) 799 (31-15/32)
Depth (I/D) mm (inch) 197 (7-25/32)
Weight Net (I/D) kg (lb) 8 (18)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8)
Drain Hose
Inner Diameter mm 16.7
Length mm 650
Indoor Heat
Exchanger
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row × Stage × FPI 2 × 15 × 17
Size (W × H × L) mm 610 × 315 × 25.4
Air Filter
Material Polypropelene
Type One-touch
Power Supply Outdoor
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
Dry Bulb Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C 32 23
Minimum °C 16 11
Heating
Maximum °C 30 –
Minimum °C 16 –
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control).
6. Specifications are subjected to change without prior notice for further improvement.
www.ampair.co.uk | sales@ampair.co.uk