92
4 To enter zone 2 area: (Press
continuously for T ≥ 5 secs)
Once T ≥ 5secs
Enter Zone2
[range (50~99)]
Enter Zone1Normal display
mode
5 Function & Options list:
Note: The functions described in the table may not be applicable to the model and may subject to change without
further notice.
Function
Options Remark
No Name
Zone 1
1 Remote control number selection A, B, C, D
2 Solar radiation sensitivity level adjustment 1, 2, 3, 4, 5
3
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [Low2]
selection
16°C ~ [High2]
4
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [High2]
selection
[Low2] ~ 30°C
5 Heat mode set temperature Low1 selection 16°C ~ [High1]
6 Heat mode set temperature High1 selection [Low1] ~ 30°C
7 Filter cleaning enable/disable selection 00 / 01
8 nanoe-G default ON enable/disable selection 00 / 01
9 Dust sensor monitoring & LED enable/disable selection 00 / 01
10 Auto restart enable/disable selection 00 / 01
11 Dust sensor sensitivity level adjustment 1, 2, 3
12 ~ 49 Reserve
Zone 2
50 ECO demo ON None (No display)
51 Light sensor check None (No display)
52 nanoe-G / ECO sensor check None (No display)
53 DOA check None (No display)
54 Odor cut control selection [Enable (01) / Disable (00)] 00 / 01
55 Frequency tolerance selection [±3Hz (03) / ±7Hz (07)] 03 / 07
56 Fixed fan speed selection during heat mode compressor OFF 00/01
57 nanoe check None (No display)
58 Heat mode thermo shift adjustment -3°C ~ 3°C
59 Others (Cool & Dry) mode thermo shift adjustment -3°C ~ 3°C
60 Deice start determination judgment temperature switching 00/01
61 Cool mode disable selection [Yes (01) / No (00)] 00/01
62 Heat mode disable selection [Yes (01) / No (00)] 00/01
63 Base pan heater selection [A / b] A / b
64
Fan speed reduction during cool mode thermo-Off [Enable (01) /
Disable (00)]
00/01
65 ~ 99 Reserve
www.ampair.co.uk | sales@ampair.co.uk