Timer control
o When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe™ X
operation status.
o When ON Timer activates during any operation, no change on current operation.
o When OFF Timer activates during any operation, all operation stops and the latest nanoe™ X operation
status is saved.
Indicator
o When nanoe™ X starts, nanoe™ X indicator ON.
Remote control receiving sound
o Normal Operation nanoe™ X Operation : Beep
o nanoe™ X Operation Normal Operation : Beep
o Stop nanoe™ X individual Operation : Beep
o nanoe™ X individual Operation Stop : Long Beep
Power failure
o During nanoe™ X individual operation, if power failure occurs, after power resumes, nanoe™ X individual
operation resumes immediately.
o During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
nanoe™ X check mode
o To enable nanoe™ X check mode, during nanoe™ X operation ON:
o During nanoe™X check mode, H67 is judged when disconnection detected. Timer LED blinks.
nanoe™ X Abnormal Detection
o Disconnection Abnormality
Abnormal detection condition
Start from 1 sec after nanoe™ X power ON, 6 secs has passed and in this 6 secs period, abnormal
signal is detected continuously for 5.9 secs.
Action after abnormal detection condition fulfilled
Disconnection counters +1, nanoe™ X power OFF for 5 minutes and then restart. However,
according to action mode and disconnection counter, below will be implemented:
o During nanoe™X Check Mode: Disconnection abnormality will judged when disconnection
counter ≥ 1. Abnormal code: H67 will memorized in EEPROM, Timer LED blinking and
nanoe™ X LED Off.
o Other Than Above: Disconnection abnormality will judged when disconnection counter ≥ 3.
Abnormal code: H67 will memorized in EEPROM and nanoe™ X LED OF
F, Timer LED not
blinking.
Disconnection counters clear condition >
Disconnection counter will be cleared when operation stop. (Not nanoe™ X Check Mode)
Normal display mode
Transmit
“NANOE™ X CHECK” code
Press SW (t ≥ 0 secs)
When SW pressed continuously for t ≥ 5 secs to enter service zone
and press
SW’s to choose function 57
SET