21.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230V
21.2.1 CS-TZ20ZKEW CU-TZ20ZKE
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
High Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
-20 -15 -10 -5 0 5 10 15
-20 -15 -10 -5 0 5 10 15
-20 -15 -10 -5 0 5 10 15
26
28
30
32
34
36
38
40
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25
3.50
0.50
1.00
1.50
2.00
2.50
3.00

Table of Contents