14.4 Airflow Direction 
  There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by 
vertical vanes). 
  Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat 
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using 
remote control). 
14.4.1 Vertical Airflow 
 
(TZ20/25/35/42/50ZK  RZ25/35/50ZK) 
 
Operation 
Mode 
Airflow Direction 
Inner Vane Angle (°) 
measured from reference point 
Outer Vane Angle (°) 
measured from reference point 
1  2  3  4  5  1  2  3  4  5 
Cooling 
AUTO 
Not yet achieve  
set temp. 
5 ~ 45  0 ~ 40 
Achieve set temp.  5  0 
SWING  5 ~ 45  0 ~ 40 
MANUAL  5  21  30  38  45  0  17  25  33  40 
Soft Dry 
AUTO 
Not yet achieve  
set temp. 
5 ~ 45  0 ~ 40 
Achieve set temp.  5  0 
SWING  5 ~ 45  0 ~ 40 
MANUAL  5  21  30  38  45  0  17  25  33  40 
Heating 
AUTO 
A  21  17 
B  52  47 
C  21  17 
SWING 
Discharge air temp. 
is cold 
21  17 
Discharge air temp. 
is warm 
41 ~ 61  36 ~ 56 
MANUAL  21  31  41  52  61  17  26  36  47  56 
 
(TZ60/71ZK) 
 
Operation 
Mode 
Airflow Direction 
Inner Vane Angle (°)  Outer Vane Angle (°) 
1  2  3  4  5  1  2  3  4  5 
Cooling/ 
Dry 
Auto 
Not yet achieve 
set temperature 
13 ~ 52  6 ~ 34 
Achieve set 
temperature 
13  6 
Auto Swing  13 ~ 52  6 ~ 34 
Manual  13  20  31  42  52  6  17  23  28  34 
Heating 
Manual  20  27  35  53  65  17  25  34  39  49 
Auto 
A  20  17 
B  35  34 
C  20  17 
Air Swing 
Lower Evaporator 
Temperature Zone 
20  17 
Higher Evaporator 
Temperature Zone 
35 ~ 65  34 ~ 49