112 
  Timer control 
o  When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe™ X 
operation status. 
o  When ON Timer activates during any operation, no change on current operation. 
o  When OFF Timer activates during any operation, all operation stops and the latest nanoe™ X operation 
status is saved. 
 
  Indicator 
o  When nanoe™ X starts, nanoe™ X indicator ON. 
 
  Remote control receiving sound 
o  Normal Operation     nanoe™ X Operation          : Beep 
o  nanoe™ X Operation     Normal Operation           : Beep 
o   Stop         nanoe™ X individual Operation       : Beep 
o  nanoe™ X individual Operation   Stop       : Long Beep 
 
  Power failure 
o  During nanoe™ X individual operation, if power failure occurs, after power resumes, nanoe™ X individual 
operation resumes immediately. 
o  During combination operation, if power failure occurs, after power resumes, combination operation resume 
immediately. 
 
  nanoe™ X check mode 
o  To enable nanoe™ X check mode, during nanoe™ X operation ON: 
 
 
 
o  During nanoe™X check mode, H67 is judged when disconnection detected. Timer LED blinks. 
 
  nanoe™ X Abnormal Detection 
o  Disconnection Abnormality 
  Abnormal detection condition 
  Start from 1 sec after nanoe™ X power ON, 6 secs has passed and in this 6 secs period, abnormal 
signal is detected continuously for 5.9 secs. 
  Action after abnormal detection condition fulfilled 
  Disconnection counters +1, nanoe™ X power OFF for 5 minutes and then restart. However, 
according to action mode and disconnection counter, below will be implemented: 
o  During nanoe™X Check Mode: Disconnection abnormality will judged when disconnection 
counter ≥ 1. Abnormal code: H67 will memorized in EEPROM, Timer LED blinking and  
nanoe™ X LED Off. 
o  Other Than Above: Disconnection abnormality will judged when disconnection counter ≥ 3. 
Abnormal code: H67 will memorized in EEPROM and nanoe™ X LED OF
F, Timer LED not 
blinking. 
  Disconnection counters clear condition > 
  Disconnection counter will be cleared when operation stop. (Not nanoe™ X Check Mode) 
 
Normal display mode
Transmit
“NANOE™ X CHECK” code
Press     SW (t ≥ 0 secs) 
When     SW pressed continuously for t ≥ 5 secs to enter service zone  
and press   
SW’s to choose function 57
SET