8.13. Random Auto Restart Control
If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
It will start with previous operation mode and airflow direction.
If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
This Random Auto Restart Control is not available when Timer is set.
This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.14. Remote Control Signal Receiving Sound
Long beep sound will be heard when:-
Stopping the air conditioner using OFF/ON operation button.
Stopping the Quiet Mode.
Stopping the Powerful Mode.
Stopping the Ion Mode.
Short beep sound will be heard for others setting.