2.2. Indoor Unit
Automatic Operation Button
Press for < 5 second to operate Automatic
operation mode. Used when the remote
control cannot be used.
Press for 5 second to operate Cooling
operation mode and compressor force to on
(beep sound will heard). Used when test
running or servicing.
Within 20 second of Cooling operation, press
continuously for 5 second to enter various
setting mode. beep, beep sound will be
heard. (Used to toggle remote control signal
receiving sound or select remote control
transmission code).
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green) ............. Lights up in operation,
blinks in Automatic
Operation judging.
TIMER
(Orange) ............ Lights up in Timer
Setting.
QUIET
(Orange) ............. Lights up in Quiet
Operation.
POWERFUL
(Orange) ...... Lights up in Powerful
Operation.
ION
(Green) .................. Lights up in Ionizer
Operation.
SUPER
ALLERU-BUSTER
(Blue) ... Lights up in operation.
7 Minutes Time Save Control
To reduce the built up humidity inside the
room.
Anti-Dew Formation Control
Anti-Dew Formation Control for indoor unit
discharge area.
Timer Operation
Delay OFF/ON Timer control.
Ionizer Operation
Generate and discharge negative ion.
Powerful Operation
Reaches the desired room temperature
quickly.
Operation Mode
Cooling, Soft Dry and Automatic Operation.
Anti-Freezing Control
To prevent indoor heat exchanger from
freezing.
Random Auto Restart Control
Unit will be restarted, when resume from
power failure, at previous setting.
Indoor Fan Speed Control
Manual control fan speed (High, Medium and
Low).
Automatic fan speed.
Vertical airflow control can be adjusted
automatically or manually by remote control.
Horizontal airflow control can be adjusted
automatically or manually by remote control.
Airflow Direction Control
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Quiet Operation
To provide quiet operation.
CS-V18DKE CU-V18DKE / CS-V24DKE CU-V24DKE
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-V18DKE and is the answer not in the manual?

Panasonic CS-V18DKE Specifications

General IconGeneral
BrandPanasonic
ModelCS-V18DKE
CategoryAir Conditioner
LanguageEnglish

Related product manuals