14 Technical Data
14.1. Thermostat Characteristics
14.1.1. CS-V18DKE CS-V24DKE
14.2. Sensible Capacity Chart
CS-V18DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 5.26 3.99 1.49 4.91 3.82 1.61 4.57 3.67 1.72 4.16 3.49 1.85
19.0°C 5.30 1.63
19.5°C 5.77 4.17 1.52 5.40 4.01 1.64 5.02 3.86 1.75 4.56 3.67 1.89
22.0°C 6.29 4.33 1.55 5.88 4.16 1.67 5.47 4.01 1.78 4.97 3.83 1.92
CS-V24DKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 6.97 5.29 2.38 6.52 5.07 2.56 6.06 4.87 2.74 5.51 4.63 2.96
19.0°C 7.03 2.60
19.5°C 7.66 5.54 2.43 7.16 5.32 2.61 6.66 5.12 2.79 6.05 4.87 3.01
22.0°C 8.34 5.74 2.47 7.80 5.52 2.66 7.25 5.33 2.84 6.59 5.08 3.07
TC - Total Cooling Capacity (kW) Indoor 27°C/19°C
SHC - Sensible Heat Capacity (kW) Outdoor 35°C/24°C
IP - Input Power (kW)
61