– 2 –
ENGLISH
1. APPLICABLE MODEL NO. TABLE
NOTE
Auto-descent panel is available for the above models. Only applicable for wired remote control. (CZ-BTA01P includes auto-
descent panel & wired remote control).
Notes on indoor unit
Standard model
The above indoor unit models can be connected to the heat pump outdoor unit models and also cooling outdoor
unit models.
Use under the following conditions:
5.1P4BB41W-SC5PBB41W-UCP10TB-ZC1V042zH05P15LR-ZCP15DR-ZC
0.2P4BB81W-SC5PBB81W-UCP10TB-ZC1 V042~022zH05P15LR-ZCP15DR-ZC
5.2P4BB42W-SC5PBB42W-UCP10TB-ZC1 V042~022zH05P15LR-ZCP15DR-ZC
0.3P4BB82W-SC5PBB82W-UCP10TB-ZC1 V042~022zH05P15LR-ZCP15DR-ZC
0.3P4BB82W-SC8PBB82W-UCP10TB-ZC3 V514~083zH05P15LR-ZCP15DR-ZC
0.4P4BB43W-SC5PBB43W-UCP10TB-ZC1 V042~022zH05P15LR-ZCP15DR-ZC
0.4P4BB43W-SC8PBB43W-UCP10TB-ZC3 V514~083zH05P15LR-ZCP15DR-ZC
0.5P4BB34W-SC8PBB34W-UCP10TB-ZC3 V514~083zH05P15LR-ZCP15DR-ZC
0.6P4BB05W-SC8PBB05W-UCP10TB-ZC3 V514~083zH05P15LR-ZCP15DR-ZC
5.1P4BB41W-SC5PBB41V-UCP10TB-ZC1 V042~022zH05P10LR-ZCP15DR-ZC
0.2P4BB81W-SC5PBB81V-UCP10TB-ZC1 V042~022zH05P10LR-ZCP15DR-ZC
5.2P4BB42W-SC5PBB42V-UCP10TB-ZC1 V042~022zH05P10LR-ZCP15DR-ZC
5.2P4BB42W-SC8PBB42V-UCP10TB-ZC3 V514~083zH05P10LR-ZCP15DR-ZC
0.3P4BB82W-SC5PBB82V-UCP10TB-ZC1 V042~022zH05P10LR-ZCP15DR-ZC
0.3P4BB82W-SC8PBB82V-UCP10TB-ZC3 V514~083zH05P10LR-ZCP15DR-ZC
0.4P4BB43W-SC5PBB43V-UCP10TB-ZC1 V042~022zH05P10LR-ZCP15DR-ZC
0.4P4BB43W-SC8PBB43V-UCP10TB-ZC3 V514~083zH05P10LR-ZCP15DR-ZC
0.5P4BB34W-SC8PBB34V-UCP10TB-ZC3 V514~083zH05P10LR-ZCP15DR-ZC
0.6P4BB05W-SC8PBB05V-UCP10TB-ZC3 V514~083zH05P10LR-ZCP15DR-ZC
Type
Heat
pump
Cooling
Only
HP
Indoor unit
model name
Outdoor unit
model name
Panel
Power source
Phase Voltage
Frequency Wireless
Wired
Remote control
(Optional parts)
Cooling Operation
Heating Operation
Indoor temperature range: 21 to 32°C
The heat-exchanger freezes in the indoor unit if you operate it continuously at 21°C or below and it causes
water leakage occasionally.
Outside air temperature range: –5 to 43°C
Indoor temperature range: 16 to 27°C
Outside air temperature range: –10 to 24°C
Operation is occasionally interrupted when the unit heats at 24°C or above (For protection purpose).
Cooling Operation
Heating Operation
Indoor temperature range: 21 to 32°C
The heat-exchanger freezes in the indoor unit if you operate it continuously at 21°C or below and it causes
water leakage occasionally.
Outside air temperature range: 10 to 43°C
Indoor temperature range: 16 to 27°C
Outside air temperature range: –5 to 24°C
Operation is occasionally interrupted when the unit heats at 24°C or above (For protection purpose).
Model (50Hz) - CU-W24BBP5, CU-W28BBP5/8, CU-W34BBP5/8, CU-W43BBP8,CU-W50BBP8
Model (50Hz) - CU-V24BBP5/8, CU-V28BBP5/8, CU-V34BBP5/8, CU-V43BBP8,CU-V50BBP8
Model (50Hz) - CU-W14BBP5, CU-W18BBP5
Model (50Hz) - CU-V14BBP5, CU-V18BBP5
O-W18BB4P-1(E) (001-009) 7/2/2003, 12:422

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-W43BB4P and is the answer not in the manual?

Panasonic CS-W43BB4P Specifications

General IconGeneral
BrandPanasonic
ModelCS-W43BB4P
CategoryAir Conditioner
LanguageEnglish

Related product manuals