12
3. Specifications
Model
Indoor CS-Z20VKEW / CS-XZ20VKEW CS-Z25VKEW / CS-XZ25VKEW
Outdoor CU-Z20VKE CU-Z25VKE
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.75 2.05 2.40 0.85 2.50 3.20
BTU/h 2560 6990 8180 2900 8530 10900
Kcal/h 650 1760 2060 730 2150 2750
Running Current A – 2.15 – – 2.50 –
Input Power W 240 450 555 240 520 790
Annual Consumption kWh – 225 – – 260 –
EER
W/W 3.13 4.56 4.32 3.54 4.81 4.05
BTU/hW 10.67 15.53 14.74 12.08 16.40 13.80
Kcal/hW 2.71 3.91 3.71 3.04 4.13 3.48
ErP
Pdesign kW 2.1 2.5
SEER (W/W) 7.5 8.5
Annual
Consumption
kWh 98 103
Class A++ A+++
Power Factor % – 91 – – 90 –
Indoor Noise (H / L / QLo)
dB-A 37 / 24 / 19 39 / 25 / 19
Power Level dB 53 / – 55 / –
Outdoor Noise (H / L)
dB-A 45 / – 46 / –
Power Level dB 60 / – 61 / –
Heating
Capacity
kW 0.70 2.80 4.00 0.80 3.40 5.00
BTU/h 2390 9550 13600 2730 11600 17100
Kcal/h 600 2410 3440 690 2920 4300
Running Current A – 2.80 – – 3.30 –
Input Power W 180 620 990 180 710 1.26k
COP
W/W 3.89 4.52 4.04 4.44 4.79 3.97
BTU/hW 13.28 15.40 13.74 15.17 16.34 13.57
Kcal/hW 3.33 3.89 3.47 3.83 4.11 3.41
ErP
Pdesign kW 2.1 2.7
Tbivalent °C -10 -10
SCOP (W/W) 4.7 5.1
Annual
Consumption
kWh 626 741
Class A++ A+++
Power Factor % – 96 – – 94 –
Indoor Noise (H / L / QLo)
dB-A 38 / 25 / 19 41 / 27 / 19
Power Level dB 54 / – 57 / –
Outdoor Noise (H / L)
dB-A 46 / – 47 / –
Power Level dB 61 / – 62 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 2.90 / 870 / 3.33 3.62 / 1.12k / 3.23
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.38 / 880 / 2.70 2.95 / 1.15k / 2.57
Max Current (A) / Max Input Power (W) 4.10 / 990 5.7 / 1.26k
Starting Current (A) 2.80 3.30