18
Model
Indoor CS-Z50VKEW / CS-XZ50VKEW CS-Z71VKEW
Outdoor CU-Z50VKE CU-Z71VKE
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.98 5.00 6.00 0.98 7.10 8.50
BTU/h 3340 17100 20500 3340 24200 29000
Kcal/h 840 4300 5160 840 6110 7310
Running Current A – 6.30 – – 9.70 –
Input Power W 280 1.41k 1.95k 420 2.17k 2.90k
Annual Consumption kWh – 705 – – 1085 –
EER
W/W 3.50 3.55 3.08 2.33 3.27 2.93
BTU/hW 11.93 12.13 10.51 7.95 11.15 10.00
Kcal/hW 3.00 3.05 2.65 2.00 2.82 2.52
ErP
Pdesign kW 5.0 7.1
SEER (W/W) 7.9 6.5
Annual
Consumption
kWh 222 382
Class A++ A++
Power Factor % – 97 – – 97 –
Indoor Noise (H / L / QLo)
dB-A 44 / 37 / 30 47 / 38 / 30
Power Level dB 60 / – 63 / –
Outdoor Noise (H / L)
dB-A 47 / – 52 / –
Power Level dB 62 / – 66 / –
Heating
Capacity
kW 0.98 5.80 8.00 0.98 8.60 10.20
BTU/h 3340 19800 27300 3340 29300 34800
Kcal/h 840 4990 6880 840 7400 8770
Running Current A – 6.50 – – 10.30 –
Input Power W 340 1.44k 2.53k 400 2.35k 2.95k
COP
W/W 2.88 4.03 3.16 2.45 3.66 3.46
BTU/hW 9.82 13.75 10.79 8.35 12.47 11.80
Kcal/hW 2.47 3.47 2.72 2.10 3.15 2.97
ErP
Pdesign kW 4.2 5.5
Tbivalent °C -10 -10
SCOP (W/W) 4.7 4.2
Annual
Consumption
kWh 1251 1833
Class A++ A+
Power Factor % – 96 – – 99 –
Indoor Noise (H / L / QLo)
dB-A 44 / 37 / 30 47 / 38 / 30
Power Level dB 60 / – 63 / –
Outdoor Noise (H / L)
dB-A 47 / – 54 / –
Power Level dB 62 / – 68 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 5.80 / 2.24k / 2.59 7.39 / 2.52k / 2.93
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 4.80 / 2.10k / 2.29 6.31 / 2.50k / 2.52
Max Current (A) / Max Input Power (W) 11.1 / 2.53k 15.6 / 3.38k
Starting Current (A) 6.50 10.30