14.2 Quiet Operation (Cooling Mode/Cooling area of Soft Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When “quiet” button at remote control is pressed.
b. Quiet operation stop condition
1 When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.
2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5 During quiet operation, if timer “on” activates, quiet operation maintains.
6 After off, when on back, quiet operation is not memorised.
C. Control contents
1 Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2 Manual fan speed for quiet operation is 1 step from setting fan speed.
3 Compressor frequency reduced.
14.2.1 Quiet operation (Heating)
A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When “quiet” button at remote control is pressed.
b. Quiet operation stop condition
1 When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.
2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5 During quiet operation, if timer “on” activates, quiet operation maintains.
6 After off, when on back, quiet operation is not memorised.
C. Control contents
a. Fan Speed Auto
Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger.
Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
b. Fan Speed Manual
Manual fan speed for quiet operation is - 1 step from setting fan speed.
c. Compressor frequency reduced.

Table of Contents

Other manuals for Panasonic CS-Z25UFEAW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-Z25UFEAW and is the answer not in the manual?

Panasonic CS-Z25UFEAW Specifications

General IconGeneral
BrandPanasonic
ModelCS-Z25UFEAW
CategoryAir Conditioner
LanguageEnglish

Related product manuals