19
Model
Indoor CS-Z50YKEA
Outdoor CU-Z50YKEA
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.98 5.00 6.00
BTU/h 3340 17100 20500
kcal/h 840 4300 5160
Running Current A - 6.00 -
Input Power W 250 1.36k 1.90k
Annual Consumption kWh - 680 -
EER CLASS - A -
EER
W/W 3.92 3.68 3.16
BTU/hW 13.36 12.57 10.79
kcal/hW 3.36 3.16 2.72
ErP
Pdesign kW 5.0
SEER (W/W) 8.6
Annual Consumption kWh 203
Class A+++
Power Factor % - 99 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 44 / 37 / 30
Power Level dB (A) 60 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 48 / - / -
Power Level dB (A) 63 / - / -
Heating
Capacity
kW 0.98 5.80 8.00
BTU/h 3340 19800 27300
kcal/h 840 4990 6880
Running Current A - 6.30 -
Input Power W 230 1.42k 2.39k
COP CLASS - A -
COP
W/W 4.26 4.08 3.35
BTU/hW 14.52 13.94 11.42
kcal/hW 3.65 3.51 2.88
ErP
Pdesign kW 4.2
Tbivalent °C -10
SCOP (W/W) 4.6
Annual Consumption kWh 1278
Class A++
Power Factor % - 98 -
Indoor Noise (H / L / QLo)
Pressure Level dB (A) 44 / 37 / 30
Power Level dB (A) 60 / - / -
Outdoor Noise (H / L / QLo)
Pressure Level dB (A) 50 / - / -
Power Level dB (A) 65 / - / -
LOW Temp: Capacity (kW) / I. Power (W) / COP 5.80 / 2.12k / 2.74
EXTR LOW Temp: Capacity (kW) / I. Power (W) / COP 4.80 / 1.88k / 2.55
Max Current (A) / Max Input Power (W) 10.5 / 2.39k
Starting Current (A) 6.30