1 Features
·
Product
A single OUTDOOR unit enables air conditioning of up to four separate rooms
Inverter controlled for High energy efficiency and optimal comfort
E - scroll compressor - guarding against global warning
New refrigerant R410A is used for protecting ozone layer
Recyclable design - non foamed polystyrene packing, lead - free P.C. Board
Quiet - running OUTDOOR unit
Luminous remote controller
Quiet mode
Powerful mode
Sleep timer (7-hour delay off)
Odour wash
24-hour on & off real setting timer
·
Serviceability
Self diagnosis
Test Run at both Cooling and Heating rated frequency
Test Run at both of INDOOR and OUTDOOR unit’s
·
Quality Improvement
Abnormal wiring or piping connection detection
2 About Lead Free Solder (PbF)
2.1. DISTINCTION OF PbF P.C. BOARD
P.C. Boards (manufactured) using lead free solder will have a PbF stamp on the P.C. Board.
2.2. CAUTION
·
Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70 °F (30 - 40 °C) higher.
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
·
Pb free solder will tend to splash when heated too high (about 1100 °F/ 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
3
CS-ME7CKPG / CS-ME10CKPG / CS-ME12CKPG / CS-ME14CKPG / CS-ME18CKPG / CU-2E15CBPG / CU-2E18CBPG / CU-3E23CBPG / CU-4E27CBPG