88
Making Settings (Do with unit stopped)
(1) Holding down the swing/flap ( ) + OFF timer ( ) + mode select ( ) buttons at the same time for
4 or more seconds will open the setting screen. (See figure below.)
(2) Use the Temperature setting buttons / ( ) to select the number of the item to be set.
(3) Use the ON timer buttons / ( ) to change settings.
(4) The settings are saved with the once/every day button ( ). When this is done, the SET displayed on the LCD
changes from blinking to lighting.
(5) If other settings are to be changed, repeat steps (2) to (4).
(6) When all settings have been made, press the start/stop ( ) button.
Operation procedure and
function display
Item
Number
(1)
(2)
(6)
(3)
(4)
Detected contents Set Contents
Factory
setting
1 Operation Mode
2 Flap Display
(No Display)
(*1)
3 Select Fan Speed
(No Display)
4 Display of Set
Temperature
°C °F Setting Off (*2) °C
5 Time Display 24 Hour (No Display)
AM/PM 24 Hour
6 Ventilation Fan
ON/OFF
OFF (No Display)
ON OFF
(*3)
03C°53 ot 50xaM pmet looC7
81C°53 ot 50niM pmet looC8
)4*( 03C°53 ot 50xaM pmet taeH9
61C°53 ot 50niM pmet taeH01
03C°53 ot 50xaM pmet yrD11
81C°53 ot 50niM pmet yrD21
72C°53 ot 50xaM pmet otuA31
71C°53 ot 50niM pmet otuA41
15 Address Setting
Max Value
00 (ALL only)
01 to 031 06 (*5)
16 Heat temp Max
ON/OFF
JP (Heater Max Temp Change
Off)
EP (ON)
JP
Attention
*1 While the unit is in the SWING mode (swing/flap), the flap cannot be stopped in a desired position.
*2 When Setting OFF is selected, “°C” is displayed on the LCD.
*3 You can toggle between ON and OFF by pressing ventilation “( )” button for 4 seconds or more.
*4 If the Heater Max ON/OFF setting is not changed to EP (ON), the setting change will not be reflected.
*5 This is the number of addresses that can be set in the address change mode. Do not set it to 07 or above.
Only available to CZ-RWSK2, CZ-RWSU3
Sec8.indd31 2012/02/2816:14:03
SM830256-00_Single_欧州小筺体 TD&SM.indb 25 16/12/28 13:40:36
Test Operation
Preparation: Turn on the circuit breaker of units and then turn the power on. After the power is turnedon, remote
controller operation is ignored for approx. 1 minute because setting is being made.
This is not malfunction. (Contents received while setting are disabled.)
1. To start test operation, press and hold the emergency operation button for 10 seconds.
2. The indication lamps (OPERATION, TIMER, STANDBY) blink during test operation.
3. To finish test operation, press and hold the emergency operation button for 10 seconds.
Attention
Do not use this mode for purposes other than the test operation.
(To prevent overload of the units)
Read the installation instructions supplied with the units.
Any of the Heat, Cool and Fan operations can only be performed.
Temperature cannot be changed.
The test operation mode is automatically turned off in 60 minutes.
(To prevent continuous test operation)
Outdoor units do not operate for approx. 3 minutes after the power is turned on or operation is stopped.
8-38
SM830276-00_欧州向け R32シングル TD&SM.indb 38 19/02/18 11:16:12